华润风电(海原)有限公司“11·12”风电项目瞒报事故调查报告(转载)
Read record, response & limits
Investigation-report reproduction: assembly/operation failures
The reproduced investigation identifies an XGC2100W in the November 2019 fatal assembly accident. Its inspection was valid. Findings concern assembly procedure, operator action, absent observation and site management.
Outcome and response
Investigation reproduced; government original not retrieved
Concealment findings concern project companies and personnel identified in the report, not XCMG. Valid inspection and absence of obvious damage marks do not establish a general product-quality conclusion.
Reproduced full report: equipment, event, causes and responsibility sections
Sections 一(三), 二(一) and 五; original event 2019-11-12