吴忠太阳山开发区宁夏聚鑫起重吊装有限公司“1·8”一般起重伤害事故调查报告
Read record, response & limits
Official incident: XCMG site presence is not causation
The report lists XZJ5507JQZ80 and XGC650 among inspected site equipment. Wind-turbine blade-root connection bolts fractured during blade-bearing replacement. Findings concern a single-sling support method and unsafe work-zone controls.
Outcome and response
Official investigation finding
The fractured bolts are turbine-blade connections, not XCMG crane bolts. The report does not assign a causal defect to either listed XCMG crane.
Original PDF equipment table, event description and causes
PDF pages 8–10 and 12–14; event 2026-01-08